+86-15105800333

Autoclave Steam Sterilizer Pressure Gauge

Sterile Processing Instrumentation

Autoclave Steam Sterilizer Pressure Gauge

A high-temperature-rated chamber pressure gauge confirms the steam pressure that underpins reliable sterilization cycles, giving central sterile supply department technicians and biomedical engineers a dependable readout through thousands of high-heat, high-humidity autoclave cycles.

ISO9001:2015 CE Certified RoHS Compliant MES Traced High-Temp Rated Cycle-Tested

Related Products

Explore our full range of pressure gauge solutions

Product Introduction

Precision instrumentation engineered for autoclave steam sterilizer pressure gauge applications

The Autoclave Steam Sterilizer Pressure Gauge is built to withstand the specific combination of high temperature, high humidity, and rapid pressure cycling that defines steam sterilizer chamber duty, an operating environment considerably more punishing than a standard industrial steam gauge application because of the sheer frequency of cycling — a busy central sterile supply department autoclave may complete several full pressure and temperature cycles every single day, year after year.

A stainless steel Bourdon tube and movement are selected specifically for corrosion resistance against the pure steam and occasional trace sterilant chemistry present in the chamber, while high-temperature-rated seals and gasket materials prevent the seal degradation that causes slow steam leakage and reading drift in gauges not specifically designed for this duty. The dial scale is calibrated to align pressure directly against the standard sterilization temperature relationship, letting technicians cross-check that the chamber has reached both the correct pressure and corresponding temperature for a validated cycle.

Every gauge is cycle-tested in our 100,000-level clean workshop through repeated simulated sterilization cycles — rapid pressurization, high-temperature hold, and rapid depressurization — before being released to production, catching any seal or movement weakness that would only appear after months of real autoclave service. Calibration and cycle-test data for every unit is logged in our Advanced MES digital tracking system against its serial number, supporting the biomedical engineering equipment records that sterile processing departments must maintain for accreditation.

The gauge is available in both chamber-integrated and control panel remote-mount configurations to suit tabletop autoclaves, large bulk sterilizers, and washer-disinfector combination units, with connection sizing matched to common autoclave manufacturer chamber port standards.

Core Advantages

Engineered for reliability where it matters most

0-4 Bar
Typical Chamber Pressure Range
+180°C
Rated Continuous Temperature
Cycle-Tested
Simulated Sterilization Cycling
  • High-Temperature Seal Rating — Seals and gasket materials specifically selected to prevent leakage and drift under sustained sterilization chamber heat
  • Corrosion-Resistant Stainless Movement — Bourdon tube and internals resist attack from pure steam and trace sterilant chemistry present in the chamber
  • Pressure-Temperature Cross-Reference Scale — Dial aligns chamber pressure directly against standard sterilization temperature for fast cycle verification
  • Simulated Cycle-Tested Before Shipment — Every unit undergoes repeated rapid pressurization and depressurization cycling to catch weaknesses before installation
  • Multiple Autoclave Configurations — Available for chamber-integrated and remote panel-mount installation across tabletop and large bulk sterilizers
  • MES Traced Production — Serial-linked quality data from raw material to shipment for full after-sale traceability

Specifications

Standard technical parameters

Dial Size2.5" (63mm), 4.0" (100mm)
Accuracy ClassClass 1.6 Full Scale (Class 1.0 on request)
Pressure Range0-4 Bar, 0-6 Bar (custom ranges available)
Rated Continuous TemperatureUp to +180°C at process connection
Bourdon Tube316L Stainless Steel
Seal MaterialHigh-Temperature Rated PTFE / Silicone
Process Connection1/4" or 1/2" NPT / BSPT, chamber-matched
Case Material304 Stainless Steel
Dial MarkingPressure / Temperature Cross-Reference Scale
Cycle RatingTested for High-Frequency Daily Sterilization Cycling

Technical Summary

Order & production details

MOQ200 Pieces (Standard Range Models)
Lead Time22-28 Days (simulated cycle-testing process)
PackagingIndividual boxes with connection thread protective cap
CertificationsISO9001:2015, CE, RoHS Compliant
Raw Materials316L Stainless Steel, High-Temperature PTFE/Silicone Seals
CustomizationPressure range, connection thread, mounting configuration
Port of ExportNingbo / Shanghai
Payment TermsT/T, L/C at Sight, Western Union

Our Partners

Trusted by leading brands worldwide

Industrial Applications

Where autoclave steam sterilizer pressure gauge performance is mission-critical

Central Sterile Supply Department Autoclaves

Primary chamber pressure indication for high-cycle bulk sterilizers processing surgical instrument trays

Tabletop Laboratory Autoclaves

Compact gauge configuration suited to benchtop sterilizer units in clinical and research laboratory settings

Washer-Disinfector Combination Units

Monitors chamber pressure during the thermal disinfection phase of combined washing and disinfection cycles

Dental Clinic Sterilizers

Confirms cycle pressure for compact chairside sterilization equipment used in dental practice settings

Pharmaceutical Terminal Sterilization Chambers

Monitors chamber pressure for terminal moist-heat sterilization of pharmaceutical products and packaging

Technical Highlights & QC

Every unit validated for zero-defect performance

  • Simulated Sterilization Cycle Testing: Every unit undergoes repeated rapid pressurization, high-temperature hold, and depressurization cycling before release.
  • High-Temperature Seal Verification: Seal materials are tested at sustained rated temperature to confirm no degradation-related leakage develops.
  • Corrosion Resistance Check: Wetted stainless components are inspected for resistance to pure steam and representative sterilant chemistry.
  • Pressure-Temperature Scale Cross-Check: Dial scale printing is verified against the standard saturated steam pressure-temperature relationship.
  • Full-Scale Linearity Sweep: Each unit is stepped through the full pressure range to verify linearity within the specified accuracy class.
  • MES Serial Tracking: Cycle test results, seal batch, and calibration data are stored digitally against each unit's serial number.

Environment & Media Compatibility

Engineered for demanding operating environments

  • Sustained High-Temperature Chamber Heat: Bourdon tube, movement, and seals are rated for the sustained high temperature typical of autoclave chamber duty.
  • High-Frequency Daily Cycling: Movement construction is specifically validated for the high cycle count typical of busy sterile processing departments.
  • High-Humidity Steam Exposure: Corrosion-resistant stainless construction withstands continuous exposure to saturated steam atmosphere.
  • Rapid Pressure Transient Events: Reinforced Bourdon tube tolerates the rapid pressurization and depressurization transients of each sterilization cycle.
  • Sterile Processing Room Cleanliness: Stainless steel case suits the cleanliness and disinfection standards typical of central sterile supply departments.
  • Trace Sterilant Chemical Exposure: Wetted materials resist the trace sterilant chemistry sometimes present in chamber steam depending on cycle type.

Pro Tips for Longevity

Installation & maintenance best practices

  • Verify Against Biological Indicators: Cross-check gauge-indicated cycle parameters against biological and chemical indicator results as part of routine sterilization assurance.
  • Include in Preventive Maintenance Schedules: Add the gauge to your autoclave's scheduled preventive maintenance rounds alongside chamber and door seal inspections.
  • Watch for Slow Pressure Bleed: A gauge that fails to hold steady pressure during the sterilization hold phase may indicate a chamber or gauge seal issue requiring investigation.
  • Do Not Substitute a Standard Industrial Gauge: Always replace with a sterilizer-rated gauge specifically designed for high-cycle, high-temperature autoclave duty.
  • Document Cycle Anomalies Immediately: Record any pressure reading anomaly per your sterile processing department's quality procedure for cycle failure investigation.
  • Schedule Annual Calibration Verification: Given the safety-critical nature of sterilization assurance, verify calibration annually against a certified reference standard.

Payment & Logistics

Reliable global supply chain from factory to your site

  • Flexible Payment Terms: We support T/T (30% deposit, balance before shipment), L/C at sight for large orders, and secure B2B trade assurance platforms for new customers.
  • Global Freight Options: Sea freight from Ningbo or Shanghai for bulk orders; DHL, FedEx, or UPS air express for urgent sample and small-batch shipments.
  • Threaded Connection Protected Packaging: Each gauge ships with a protective cap over the connection thread to prevent damage or contamination during transit.
  • Full Export Documentation: Commercial invoice, packing list, certificate of origin (CO), material certificates, and CE declaration of conformity provided with every shipment.
  • Sample Lead Time: Standard range samples available within 10-12 working days given the simulated cycle-testing process.
  • After-Sales Support: Our technical team provides installation guidance and cycle-test documentation to support your sterile processing compliance records.

About Us

Zhoushan Jiaerling Meter Co., Ltd. — 20 years of precision manufacturing

Zhoushan Jiaerling Meter Co., Ltd.

Zhoushan Jiaerling Meter Co., Ltd. was established in 2004. It is China Autoclave Steam Sterilizer Pressure Gauge Manufacturers and Wholesale Autoclave Steam Sterilizer Pressure Gauge Factory, which is a high-tech enterprise integrating design, research and development, manufacturing, import and export trade.

The company is located in Zhoushan City, Zhejiang Province, covering an area of 15,000 square meters, equipped with a 100,000-level clean workshop, conventional production and assembly workshop, automated production workshop, new laboratory and comprehensive office building.

After more than 20 years of hard work and development, the company has a stable design and development, production team, and advanced production and testing equipment. The company specializes in the production of various types of pressure gauges with complete specifications, and the annual output of pressure gauges reaches 6 million. In order to further develop, the company not only seeks improvement in technology, but also pays more attention to product quality and after-sales service. The company's purpose is to "regard quality as life, survive by reputation, promote development by technology, and serve customers with high-quality brands". The products are sold all over the world and are well received by domestic and foreign customers.

In 2019, the company participated in the compilation of the standard T/CECS10012-2019 "Gas Heating Hot Water Boiler and Water Heater Water Circuit Components" of the China Engineering Construction Standardization Association.

Under the implementation of modern and digital enterprise management, the company has successfully introduced the advanced MES system in 2023, and the order process is fully visualized to track data, ensuring the continuity of production and improving production efficiency.

The company will continue to adhere to the principles of excellence, accuracy, reliability, continuous improvement, and meeting customer needs, hoping to share harmony and prosperity with friends across the country.

20+
01.Corporate History
15,000M²
02.Factory Area
6,000,000
03.Annual Output (Pieces)
50+
04.Export Area

Honor

Certifications and proprietary achievements

Frequently Asked Questions

Everything you need to know before specifying or ordering

What pressure range is typical for a steam sterilizer chamber?
Most standard steam sterilizers operate in the 1-3 Bar gauge pressure range corresponding to 121-134°C sterilization temperatures.
Why does the gauge need a pressure-temperature cross-reference scale?
It lets technicians quickly cross-check that both the correct pressure and corresponding saturation temperature have been reached for a valid cycle.
How many cycles is this gauge rated to withstand?
Units are simulated cycle-tested to withstand the high-frequency daily cycling typical of busy central sterile supply department use over years of service.
Can this gauge be used on a tabletop laboratory autoclave?
Yes, compact dial sizes are available specifically for benchtop and tabletop sterilizer configurations.
What causes premature gauge failure in autoclave service?
Repeated thermal cycling combined with seal degradation is the most common cause; our high-temperature-rated seals are selected specifically to resist this.
Is this gauge suitable for a washer-disinfector unit?
Yes, the same high-temperature construction suits the thermal disinfection phase pressure monitoring in washer-disinfector combination units.
How often should the gauge be recalibrated?
Annual verification is recommended given the safety-critical role of accurate cycle pressure confirmation in sterilization assurance.
What connection size is standard?
1/4" or 1/2" NPT or BSPT is standard, matched to common autoclave manufacturer chamber port sizing.
Can the gauge be supplied with cycle-test documentation?
Yes, cycle-test and calibration records referencing our testing process are available as supporting documentation for your equipment records.
Is a remote panel-mount version available for large bulk sterilizers?
Yes, remote panel-mount configurations are available in addition to the standard chamber-integrated version.

Related Information

Latest insights and industry knowledge

Espresso Machine Steam Pressure Gauge

Product Introduction Precision instrumentation

Dual Scale HVAC Pressure Gauge

Product Introduction The core of HVAC pressure

Industrial Air Compressor Pressure Gauge

Product Introduction Precision instrumentation

Pneumatic System Air Pressure Gauge

Product Introduction Precision instrumentation

Ultra Pure Water Pressure Gauge

Product Introduction Precision instrumentation

Membrane Housing Water Pressure Gauge

Product Introduction Precision instrumentation

Shockproof Liquid Filled Pressure Gauge

Product Introduction Precision instrumentation

Polypropylene Housing Diaphragm Pressure Gauge

Product Introduction Precision instrumentation

Anti Vibration Oil Filled Pressure Gauge

Product Introduction Precision instrumentation

Ready to Order or Need a Custom Chamber Configuration?

Tell our engineering team your sterilizer chamber pressure range, connection thread, and mounting configuration. We will configure the right high-temperature-rated gauge for your equipment. OEM & ODM branding available with fast sample service.

Get a Quote