Square capillary thermometers, due to their shape, can better adapt to the space requirements of specific installation locations, especially when equipment or pipe layouts are compact. Compared with traditional round dials, square meters can make more efficient use of the area in limited space and reduce the space required for installation. This design is particularly beneficial when multiple meters need to be arranged in a small space. The dial of square meters usually has a larger display area, which helps to improve the clarity of readings.
Square capillary thermometer designs usually have flexible installation options, including panel mounting, wall mounting, etc. This flexibility allows them to adapt to various installation requirements, especially in systems with customized equipment or non-standard pipe layouts. The flat design of square meters can also be installed side by side with other meters or controllers to form a neat and compact control panel.
In certain application scenarios in the HVAC industry, equipment may be affected by vibration or shock. Square meters usually have strong seismic resistance, and their stable structural design can effectively resist external vibrations, ensuring the accuracy of readings and the service life of the meter. Especially in systems that require long-term stable operation, square meters can provide more reliable performance.
Nominal size: | 48*48mm、52*46mm |
Scale range: | 0-4bar、6bar、10bar |
Accuracy class: | CL2.5 |
Capillary material: | Copper、PE |
Capillary length: | 300mm、500mm、650mm、Customizable |
Connection material: | Copper、PE |
Connection: | G1/4、M14*1、Plug-in、Customizable |
Case: | PA66/ABS |
Nominal size | 48*48mm、52*46mm |
Scale range | 0-4bar、6bar、10bar |
Accuracy class | CL2.5 |
Capillary material | Copper、PE |
Capillary length | 300mm、500mm、650mm、Customizable |
Connection material | Copper、PE |
Connection | G1/4、M14*1、Plug-in、Customizable |
Case | PA66/ABS |
Nominal size | 48*48mm、52*46mm |
Scale range | 0-4bar、6bar、10bar |
Accuracy class | CL2.5 |
Capillary material | Copper、PE |
Capillary length | 300mm、500mm、650mm、Customizable |
Connection material | Copper、PE |
Connection | G1/4、M14*1、Plug-in、Customizable |
Case | PA66/ABS |
Nominal size | 48*48mm、52*46mm |
Scale range | 0-4bar、6bar、10bar |
Accuracy class | CL2.5 |
Capillary material | Copper、PE |
Capillary length | 300mm、500mm、650mm、Customizable |
Connection material | Copper、PE |
Connection | G1/4、M14*1、Plug-in、Customizable |
Case | PA66/ABS |
Nominal size | 48*48mm、52*46mm |
Scale range | 0-4bar、6bar、10bar |
Accuracy class | CL2.5 |
Capillary material | Copper、PE |
Capillary length | 300mm、500mm、650mm、Customizable |
Connection material | Copper、PE |
Connection | G1/4、M14*1、Plug-in、Customizable |
Case | PA66/ABS |
Nominal size | 48*48mm、52*46mm |
Scale range | 0-4bar、6bar、10bar |
Accuracy class | CL2.5 |
Capillary material | Copper、PE |
Capillary length | 300mm、500mm、650mm、Customizable |
Connection material | Copper、PE |
Connection | G1/4、M14*1、Plug-in、Customizable |
Case | PA66/ABS |
Zhoushan Jiaerling Meter Co., Ltd. is China HVAC Square Capillary Thermometer Manufacturers and Wholesale HVAC Square Capillary Thermometer Factory. The company was established in 2004. It is a high-tech enterprise integrating design, research and development, manufacturing, import and export trade.
The company is located in Zhoushan City, Zhejiang Province, covering an area of ​​15,000 square meters, equipped with a 100,000-level clean workshop, conventional production and assembly workshop, automated production workshop, new laboratory and comprehensive office building.
After more than 20 years of hard work and development, the company has a stable design and development, production team, and advanced production and testing equipment. The company specializes in the production of various types of pressure gauges with complete specifications, and the annual output of pressure gauges reaches 6 million. In order to further develop, the company not only seeks improvement in technology, but also pays more attention to product quality and after-sales service. The company's purpose is to "regard quality as life, survive by reputation, promote development by technology, and serve customers with high-quality brands". The products are sold all over the world and are well received by domestic and foreign customers.
In 2019, the company participated in the compilation of the standard T/CECS10012-2019 "Gas Heating Hot Water Boiler and Water Heater Water Circuit Components" of the China Engineering Construction Standardization Association.
Under the implementation of modern and digital enterprise management, the company has successfully introduced the advanced MES system in 2023, and the order process is fully visualized to track data, ensuring the continuity of production and improving production efficiency.
The company will continue to adhere to the principles of excellence, accuracy, reliability, continuous improvement, and meeting customer needs, hoping to share harmony and prosperity with friends across the country.
As a vital guarantee for healthy drinking water in modern households, a water purifier's efficient and stable operation relies on the coordinated operation of v...
View MoreIn modern water treatment, water purifiers have become essential equipment for ensuring household drinking water safety. The performance of their core component...
View MoreIn the HVAC (heating, ventilation, and air conditioning) sector, accurate temperature measurement is the cornerstone of ensuring efficient system operation and ...
View MoreHigh Readings: Potential Cooling/Heating IssuesWhen the HVAC thermometer reading is consistently above the set point, it typically indicates that the system is ...
View MoreIn modern industrial and building environments, the accuracy of temperature monitoring is crucial. Jiaerling is committed to providing customers with high-performance HVAC Square Capillary Thermometer. The core of the product is the professional temperature measuring element, which is the heart of the thermometer and directly determines the accuracy of the measurement results. During the research and development process, we carefully select high-quality temperature measuring elements to ensure their excellent accuracy and stability. These elements can maintain consistent and reliable measurement performance over a wide temperature range to meet the needs of various demanding applications. At the same time, we implement a strict screening and testing procedure for temperature measuring elements to ensure that they meet international standards and specific customer requirements.
Capillary technology is one of the key factors in achieving high-precision temperature measurement. Jiaerling uses an advanced capillary design in the HVAC Square Capillary Thermometer, which greatly improves the thermometer's response speed and sensitivity to temperature changes. When the temperature in the system changes, the volume of the liquid or gas in the capillary changes accordingly, which in turn causes the resistance or voltage of the temperature measuring element to change. This change can be accurately converted into a temperature reading after being processed by a high-precision circuit and calculated by a complex algorithm. The application of capillary technology enables the thermometer to capture tiny temperature changes in a very short time, providing strong support for the precise control of the HVAC system.
In addition to high-quality temperature measuring elements and advanced capillary technology, Jiaerling Meter has also deeply optimized the circuit design and algorithm of HVAC Square Capillary Thermometer. We applied advanced signal processing technology and efficient filtering algorithms to effectively reduce the impact of external interference on the measurement results. The circuit has been fine-tuned and tested to ensure that the resistance or voltage changes of the temperature measuring element can be accurately read and converted into accurate temperature values. This professional circuit design and algorithm optimization enables the thermometer to maintain stable measurement performance in complex and changing environments, ensuring that customer needs are met in various application scenarios.
In order to ensure that the HVAC Square Capillary Thermometer has high-precision temperature measurement performance, Jiaerling Meter implements strict quality control measures during the production process. We have carefully controlled every production link to ensure that each product meets international standards and customer expectations. During the production process, the thermometer is fully tested and verified for performance using advanced testing equipment and instruments, including accuracy testing, stability testing, and anti-interference testing. These rigorous testing procedures ensure that the thermometer can maintain stable measurement performance in long-term use, thereby providing customers with reliable temperature monitoring solutions.
In the field of HVAC (heating, ventilation and air conditioning), the accuracy and reliability of thermometers are crucial. As a commonly used temperature measurement device, HVAC Square Capillary Thermometer may have a variety of faults that affect its performance. The following are common faults and their solutions.
Inaccurate Thermometer Display
Inaccurate thermometer display is a common problem of HVAC Square Capillary Thermometer, which is usually caused by aging, damage or external environmental interference of the temperature measuring element. To ensure the accuracy of the thermometer, it is recommended that users first check the temperature measuring element to confirm that it is intact. If damage is found, it needs to be replaced immediately. In addition, the installation location of the thermometer should also be taken seriously to avoid direct sunlight or other heat sources. Regular calibration of the thermometer is a key measure to maintain its measurement accuracy. Users should develop a regular calibration plan to ensure the working condition of the equipment.
Thermometer Readings Fluctuate Largely
Fluctuating thermometer readings may be caused by factors such as capillary blockage, circuit failure or poor sensor contact. When users encounter such problems, they should first check whether the capillary is unobstructed and clean it if necessary. At the same time, it is necessary to check whether the circuit connection is firm to ensure good contact between the sensor and the measurement system. If the problem still exists after the above inspection, it is recommended to contact professional maintenance personnel for in-depth inspection and repair to restore the normal function of the thermometer in time.
Thermometer has no display or abnormal display
No display or abnormal display may be caused by power failure, display damage or internal circuit problems. Users should first confirm that the power connection is normal, check the battery level or the working status of the power adapter. If the power supply is normal, then check whether the display is physically damaged or whether the internal circuit is faulty. In the face of complex fault problems, it is recommended to contact the after-sales service center or professional maintenance personnel of Jiaerling Instrument in time to ensure timely repair of the equipment.
Improper installation of the thermometer leads to measurement errors
The measurement accuracy of the thermometer is closely related to its installation location and method. Improper installation, such as insufficient insertion depth, incorrect installation angle or poor environmental conditions, may cause measurement errors. Jiaerling Instruments emphasizes that when installing the HVAC Square Capillary Thermometer, users should strictly follow the instructions in the product manual to ensure that the installation position is accurate and the insertion depth meets the requirements, and avoid installation in an environment susceptible to mechanical vibration or electromagnetic interference to improve the reliability of measurement.
Aging problem of thermometer after long-term use
As the use time increases, the internal components of the thermometer may age, resulting in reduced measurement accuracy or frequent failures. In order to ensure the long-term and stable operation of the thermometer, users should regularly maintain and inspect the equipment, including replacing aging components, cleaning dust and dirt, etc. In addition, it is recommended that users formulate a reasonable replacement plan based on the frequency of use of the thermometer and environmental conditions, so as to replace aging components in time and maintain the performance of the equipment.